法医学杂志 ›› 2020, Vol. 36 ›› Issue (2): 216-222.DOI: 10.12116/j.issn.1004-5619.2020.02.013

Previous Articles     Next Articles

Retention Time and Ion Abundance Ratio of 8 Common Drugs (Poisons) by LC-MS/MS Qualitative Analysis#br#

MIN Tao1, LIU Shao-dan2, XIN Guo-bin3, ZHANG Da-ming1,3   

  1. 1. School of Forensic Medicine, Shanxi Medical University, Taiyuan 030001, China; 2. Dian Institute of Forensic Science, Hangzhou 310000, China; 3. Forensic Judicial Appraisal Center of Beijing Public Security Bureau, Beijing 100192, China
  • Online:2020-04-25 Published:2020-04-28
  • Supported by:
     

Abstract: Objective To investigate the maximum allowable deviations of retention time and ion abundance ratio of the 8 common drugs (poisons) from 3 categories, poisons (methamphetamine, morphine, ketamine), benzodiazepines (estazolam, midazolam, diazepam, clonazepam) and barbiturates (phenobarbital) in blood, by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in forensic toxicology analysis. Methods The deviations of retention time and ion abundance ratio at 7 low mass concentrations, limit of detection (LOD), 2LOD, limit of quantitation (LOQ), 1.5LOQ, 2LOQ, 4LOQ and 6LOQ, were tested by LC-MS/MS after liquid-liquid extraction under the conditions of two chromatographic columns and three chromatographs. Results The deviation of absolute retention time of 98.11% of 8 drugs (poisons) in the blood samples was within the range of ±0.05 min, and that of the relative retention time of 96.21% was within the range of ±0.4%. The maximum deviation of the ion abundance ratio was highly correlated with the mass concentration. When the mass concentration of drugs (poisons) was LOQ or above, more than 95% of the absolute deviation and relative deviation of the ion abundance ratio were in the range of ±25% and ±40%, respectively; when the mass concentration was below LOQ, the range could be expanded to ±35% and ±50%, respectively. Conclusion It is recommended for the determination range of the absolute retention time deviation of 8 common drugs (poisons) to be ±0.1 min and that of the relative retention time deviation to be ±1.0%. The determination range of absolute deviation of the ion abundance ratio should be ±25% when the mass concentration is LOQ or above, and the relative deviation should be ±40%. When the mass concentration is below LOQ, the deviation determination range can be expanded to ±35% and ±50%, respectively.

 

Key words: forensic toxicology, liquid chromatography-mass spectrometry, retention time, ion abundance ratio, methamphetamine, morphine, ketamine, estazolam, midazolam, diazepam, clonazepam, phenobarbital

CLC Number: