法医学杂志 ›› 2014, Vol. 30 ›› Issue (6): 427-430.DOI: 10.3969/j.issn.1004-5619.2014.06.006

• 论著 • 上一篇    下一篇

等速肌力检测在辨别伪肢体瘫中的应用

夏  晴,高  东,黄婷婷,冉  聃   

  1. (司法部司法鉴定科学技术研究所 上海市法医学重点实验室,上海 200063)
  • 发布日期:2014-12-25 出版日期:2014-12-28
  • 通讯作者: 高东,男,博士研究生,助理研究员,主要从事法医临床学科研和鉴定工作;E-mail:gaodong811201@sina.com
  • 作者简介:夏晴(1984—),男,上海人,硕士,助理研究员,主要从事法医临床学科研和鉴定工作;E-mail:xiaqing0128@126.com
  • 基金资助:

    “十二五”国家科技支撑计划项目(2012BAK16B03)

Application of Isokinetic Muscle Testing in Identification of the Faked Paralysis

XIA QING, GAO DONG, HUANG TING-TING, RAN DAN   

  1. (Shanghai Key Laboratory of Forensic Medicine, Institute of Forensic Science, Ministry of Justice, P.R.China, Shanghai 200063, China)
  • Online:2014-12-25 Published:2014-12-28

摘要: 目的 探讨等速肌力检测在法医学鉴定中辨别伪肢体瘫的应用价值,为建立规范、统一的法医学肌力评价方法提供科学依据。 方法 选取骨折或神经损伤者57例(损伤组)和伪装者128例(伪装组),应用等速肌力测试系统对损伤组两侧膝关节与伪装组膝关节进行检测,对双侧膝关节屈、伸肌的峰力矩(peak torque,PT)、峰力矩角度(peak torque angle,PTA)进行比较,归纳两组膝关节的力矩-时间图特征。 结果 损伤组膝关节屈、伸肌的双侧PT的比较差异有统计学意义(P<0.05),PTA的比较差异无统计学意义(P>0.05);伪装组膝关节屈、伸肌的双侧PT、PTA的比较差异均有统计学意义(P<0.05)。损伤组两侧膝关节力矩-时间图主要为单峰前置型,伪装组膝关节力矩-时间图主要为多峰型。 结论 在法医学鉴定中,等速肌力检测在辨别伪肢体瘫方面可以通过力矩-时间图的相关特点进行评价。

关键词: 法医学, 偏瘫, 等速肌力

Abstract: Objective To study the application of isokinetic muscle testing in identification of the faked paralysis to provide scientific data for establishing a standard system of muscle strength in forensic medicine identification. Methods Fifty-seven patients with bone fracture or nerve damage as damaged group and 128 normal subjects pretended paralysis as faked paralyzed group were included in this study. Isokinetic muscle testing was performed on bilateral knees of all subjects in the two groups. The peak torque (PT) and peak torque angle (PTA) were compared between both sides in each group. The features of torque-time graph of two groups were classified. Results In the damaged group, the differences of PT between two sides of flexors and extensors were statistically significant (P<0.05), while the differences of PTA were not statistically significant (P>0.05). In faked paralyzed group, the differences of PT and PTA between two sides of flexors and extensors were both statistically significant (P<0.05). The torque-time graph of damaged knee presented mostly as single lead peak, while torque-time graph of the faked paralyzed knee presented mostly as multiple peaks. Conclusion The feature of torque-time graph could be useful to identify the faked paralyzed extremities in forensic authentication.

Key words: forensic medicine, hemiplegia, isokinetic muscle tests

中图分类号: