法医学杂志 ›› 2017, Vol. 33 ›› Issue (2): 148-153.DOI: 10.3969/j.issn.1004-5619.2017.02.008

• 论著 • 上一篇    下一篇

硫化氢中毒案件中血液硫离子的测定

强火生1,2,陈  航2,沈保华2,沈  敏2,向  平1,2   

  1. (1. 温州医科大学药学院,浙江 温州 325035; 2. 司法部司法鉴定科学技术研究所 上海市法医学重点实验室 上海市司法鉴定专业技术服务平台,上海 200063)
  • 发布日期:2017-04-25 出版日期:2017-04-28
  • 通讯作者: 向平,女,研究员,主要从事法医毒物学研究和鉴定;E-mail:xiangp@ssfjd.cn
  • 作者简介:强火生(1991—),男,硕士研究生,主要从事药物分析研究;E-mail:13818940774@163.com
  • 基金资助:

    十三五国家重点研发计划项目(2016YFC0800704);上海市科委资助项目(15dz1207500);上海市法医学重点实验室资助项目(17DZ2273200);上海市司法鉴定专业技术服务平台资助项目(16DZ2290900)

Determination of Sulfide Ion in Blood from Hydrogen Sulfide Poisoning Cases

QIANG HUO-SHENG1,2, CHEN HANG2, SHEN BAO-HUA2, SHEN MIN2, XIANG PING1,2   

  1. (1. Pharmacy School of Wenzhou Medical University, Wenzhou 325035, China; 2. Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Institute of Forensic Science, Ministry of Justice, PRC, Shanghai 200063, China)
  • Online:2017-04-25 Published:2017-04-28

摘要: 目的 建立血液中硫离子的气相色谱-质谱(GC-MS)测定方法,并将其应用于实际案例。 方法 取血液0.2 mL,以1,3,5-三溴苯为内标,经五氟苄基溴衍生化后采用GC-MS分析。 结果 血液中的硫离子在0.2~40 μg/mL质量浓度范围内线性良好,最低检出限为0.05 μg/mL。健康人群、死后等不同来源的空白血液中硫离子质量浓度不高于0.05 μg/mL。3例硫化氢中毒案件中,6名死者血液中均检出硫离子,质量浓度在1.02~3.13 μg/mL。 结论 本研究建立了血液中硫离子测定方法,并成功应用于硫化氢中毒死亡案件。

关键词: 法医毒理学, 中毒, 硫化氢, 衍生化, 气相色谱-质谱联用法

Abstract: Objective To establish a gas chromatography-mass spectrometry (GC-MS) method for the determination of sulfide ion in blood and apply it to the practical cases. Methods The 1, 3, 5-tribromobenzene was selected as an internal standard, and 0.2 mL blood sample was collected and analyzed using GC-MS after α-Bromo-2, 3, 4, 5, 6-pentafluorobenzyl bromide derivatization. Results The mass concentration of sulfide ion in blood had good linearity in the range of 0.2-40 μg/mL with a limit of detection (LOD) of 0.05 μg/mL. The mass concentration of sulfide ion was less than 0.05 μg/mL in blank blood from different sources such as healthy subjects and dead cases. In 3 sulfide poisoning cases, sulfide ion was detected in the blood samples of 6 victims, and the mass concentration range was 1.02-3.13 μg/mL. Conclusion This study establishes a method for investigation of sulfide ion in blood which has been applied successfully to the cases of fatal sulfide poisonings.

Key words: forensic toxicology, poisoning, hydrogen sulfide, derivatization, gas chromatography-mass spectrometry